PROFIBUS DP Slave Communication Module

MVI46-PDPS

The MVI46-PDPS ("PROFIBUS DP Slave Communication Module") allows Allen-Bradley SLC I/O compatible processors to easily interface with a PROFIBUS DP Master device.

Features and Benefits

The PROFIBUS DP Slave (PDPS) protocol interface supports the PROFIBUS V0 Slave implementation protocol, providing powerful data transfer capability between the module and Allen-Bradley SLC processors. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.

The MVI46 module Configuration/Debug Serial port connects a PC to the module for configuration, status, monitoring, and troubleshooting (Serial cable is included with product shipment). After editing on a PC, a configuration file is downloaded and stored on the MVI46 module.

The PROFIBUS DP Slave gives access to the unit's input and output images with up to 244 bytes of Input and Output data, for a maximum of 400 bytes total. These Input and Output data blocks are mapped by the user within the inRax module's data memory allowing maximum flexibility and data transfer with other protocols.

Applications

The PROFIBUS DP slave interface enables Allen-Bradley SLC processors to interface with a PROFIBUS DP network. The MVI46-PDPS module is the ideal solution for many applications where connectivity to a PROFIBUS Master needs to be added to an SLC system. The PROFIBUS solution has been designed to address the expanding interest in Rockwell Automation and PROFIBUS in industrial applications such as those in the Water/Waste Water, Power and Oil & Gas industries, SCADA and DCS applications.

Functional Specifications

PROFIBUS Slave

  • Communication parameters
    • Baud Rate: 9.6 kbit/s12 Mbit/s
  • Supported I/O length
    • Up to 244 bytes Input data
    • Up to 244 bytes Output data
    • Total not to exceed 400 bytes.
  • Freeze Mode
  • Sync Mode
  • Auto Baud Setting
  • Configurable Parameters
    • PROFIBUS Node Address: 0 to 125
    • Data byte swapping
    • Action on loss of PROFIBUS connection
    • Comm Fail Timeout Multiplier
    • Status Data location in Internal Database
  • Status Data
    • PROFIBUS Status Data for slave
  • Physical Connection
    • PROFIBUS Connector
    • Standard PROFIBUS DB-9F communication connector. Cable connection matches PROFIBUS pin out specification.

Ordering Information

MVI46-PDPS PROFIBUS DP Slave Communication Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Related Information

ProSoft Configuration Builder

Image Gallery



ProSoft Technology, Inc. Copyright © 2003 - 2009

Return to Non-Printable Page