Modbus Master/Slave Communications ModuleMVI71-MCMThe MVI71 Modbus Master/Slave Communication Module allows Rockwell Automation PLC processors to interface easily with other Modbus protocol compatible devices. Compatible devices include not only Modicon PLCs (which all support the Modbus protocol) but also a wide assortment of end devices. The module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus network. A 5000-word register space in the module exchanges data between the processor and the Modbus network. Features and BenefitsThe inRAx Modbus Master/Slave Communication Module is designed to allow PLC processors to interface easily with Modbus protocol-compatible devices and hosts. The MVI71-MCM module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the PLC processor is asynchronous from the actions on the Modbus network. A 5000-word register space in the module exchanges data between the processor and the Modbus network. Many host SCADA packages support the Modbus protocol, while devices commonly supporting the protocol include several PLCs, as well as many other third party devices in the marketplace. (For a partial list of devices that speak Modbus, please visit the ProSoft Tested section of the ProSoft Technology web site). General Specifications
ApplicationsApplications using the Modbus Communication Module can be found in many industrial sectors and in the following applications
Functional SpecificationsSome of the general specifications include:
Slave Specifications The MVI71-MCM module accepts Modbus function code commands of 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22 and 23 from an attached Modbus master unit. A port configured as a Modbus slave permits a remote master to interact with all data contained in the module. This data can be derived from other Modbus slave devices on the network, through a master port, or from the PLC processor. Master Specifications A port configured as a virtual Modbus master device on the MVI71-MCM module actively issues Modbus commands to other nodes on the Modbus network. One hundred commands are supported on each port. Additionally, the master ports have an optimized polling characteristic that polls slaves with communication problems less frequently. The PLC processor can be programmed to control the activity on the port by actively selecting commands from the command list to execute or issuing commands directly from the ladder logic. Hardware Specifications
Ordering Information
Distributors: Sales and Support:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ProSoft Technology, Inc. Copyright © 2003 - 2009