FA Control Network Communication Interface

MVI56-FLN

Product Description

The MVI56-FLN FA Control Network Communication Module is a single slot solution that allows Rockwell Automation ControlLogix I/O compatible processors to easily interface with other FL-net protocol compatible devices.The module implements FL-net version 2.00 (OPCN-2) defined by JEMA (The Japan Electrical Manufacturers Association) for the standard FA control network. FL-net is a master-less system and is specified for a 50 ms cycle time for 32 nodes (with 2kbit + 2kWord cyclic data in total) and up to 254 nodes can be addressed.

The MVI56-FLN module acts as a gateway between the FL-net network and the Allen-Bradley backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the FL-net network. The module's internal database can be used to exchangeup to 512 words of Area 1 cyclic data, and 8192 words of Area 2 cyclic data between the processor and the FL-net network.

Features and Benefits

  • Master-less token control method.
  • FA link protocol on Ethernet UDP/IP.
  • Cyclic data transfer: Supports virtual memory Area 1 and Area 2. The cyclic data is mapped to the modules I/O area.
  • Message transfer
    Server Functionality
    • Log data read service
    • Log data clear service
    • Network Parameter Read
    • Profile Read
    • Return Message
  • Network Management Table: According to FL-net version 2.00 specification.
  • Own-node Management Table: According to FL-net version 2.00 specification.
  • Participating Node Management Table: According to FL-net version 2.00 specification.
  • Network configurable via a text file or ProSoft Technology Configuration Builder Software
  • Status and Error information

General Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack

Applications

The MVI56-FLN module provides highly configurable FL-net capabilities to the Rockwell Automation ControlLogix platform. FL-net (OPCN-2) is a controller-level network conforming to specification Japan Electrical manufacturers Association JEM1479. Developed to focus on multi-vendor communications of programmable controllers, NC controllers, Robotic and other Motion Control systems.

Functional Specifications

  • Message transfer:
    Server Functionality
    • Log data read service
    • Log data clear service
    • Network Parameter Read
    • Return Message
    • Profile Read
  • Network Management Table: According to FL-net version 2.00 specification.
  • Own-node Management Table: According to FL-net version 2.00 specification.
  • Participating Node Management Table: According to FL-net version 2.00 specification.
  • Network configurable via a text file
  • Status and Error information

Hardware Specifications

Ethernet and CFG Ports

 

Ethernet Port

RJ45 connection
10/100 Mbit Ethernet support (auto-sensing)
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

CFG Port

RJ45 (DB-9M with supplied cable)
RS-232 only

Shipped with unit

RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for debug port

Specification

Description

Backplane Current Load

800 mA @ 5 V

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock:

30g Operational
50g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5 to 95% (non-condensing)

LED Indicators:

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Ordering Information

MVI56-FLN FA Control Network Communication Interface
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Related Information

ProSoft Configuration Builder

Image Gallery



Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested