ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Platform > ControlLogix > MVI56-S3964R
Printable Page
 

Search | Clear


Siemens 3964R Protocol

MVI56-S3964R

The MVI56 S3964R Protocol module from ProSoft Technology allows point-to-point communication between a ControlLogix controller (1756-L1, -L1Mx, L55, L6x) and a partner with 3964R (with or without RK512) communication capability.

Features and Benefits

The 3964R protocol (with or without RK512) was designed by Siemens for bi-directional data communication through a point-to-point connection. It is a peer to peer protocol with read and write access. A BCC checksum ensures the safety of the transfer.

General Specifications

  • Single Slot - 1756 backplane compatible
  • Local or remote rack
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.

Applications

The module is ideal in control configurations where there is a need for the ControlLogix controller to exchange data with other non-Rockwell Automation control devices in low speed applications.

The MVI56-3964R can communicate with or without RK512 devices using two RS-232, RS-422 communication lines (ports). The ports operate independently from each other.

Functional Specifications

  • Single-slot, ControlLogix backplane compatible
  • Multiple modules can be placed in a rack up to the chassis power supply limit
  • While in 3964R with RK512 mode on PRT1 and PRT2, DB-SEND and DB-FETCH instructions can be initiated from the ControlLogix processor or received by the communications partner
  • While in 3964R without RK512 mode on PRT1 and PRT2, data can be sent from the ControlLogix processor or be received from the communications partner
  • The maximum transfer rate is 512 bytes in any mode
  • Data byte swapping can be configured to adjust to a different word format
  • While in 3964R with RK512 mode on PRT1 and PRT2, evaluation of the header information DB (data block), DW (data word) and coordination bytes 9 and 10 is possible
  • Communication activity and diagnostics are available through LEDs and acknowledgment telegrams

Ladder Logic

Ladder logic programming in the ControlLogix processor is required in order to enable and support the Siemens 3964R protocol functionality. The ladder program handles the encoding/decoding of data transferred from the module as well as the initiation of protocol-specific functionality in the module. Example ladder programs are provided with the module to ease the implementation of the module in the user application.

Hardware Specifications

Specification

Description

Backplane Current Load

800 mA @ 5 V

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Shock:

30g Operational
50g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5 to 95% (non-condensing)

LED Indicators:

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Ordering Information

MVI56-S3964R Siemens 3964R Protocol
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Related Information

ProSoft Configuration Builder

Image Gallery



Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested