ProSoft Technology, Inc.
Home > Products > Stand-alone Gateways > Wireless > Wireless ASCII Generic Serial Gateway
Printable Page
 

Search | Clear


Wireless ASCII Generic Serial Gateway

6201-WA-ASCII

Product Description

The ProLinx Wireless ASCII Generic Serial Gateway creates a powerful wireless connection between ASCII input devices. The module provides one ASCII configurable serial port.

The PWP modules offer one-to-one or one-to-many interconnect scenarios. Data is exchanged between devices and/or networks using a shared common database and an efficient but powerful wireless protocol. This common database provides the "backbone" communications for various field devices using different networks.

The ASCII protocol driver permits the module to interface to many ASCII devices. Each ASCII port on the module is configurable to send and/or receive ASCII strings, each supporting its own individual serial network.

Product Applications

The WA-ASCII module is the ideal solution for the many applications where wireless connectivity can be used to integrate an ASCII generic serial input device into a system. Applications for the module are found in most industries, including
  • Bar code scanner interfaces
  • Weigh scale interfaces
  • Legacy ASCII protocol connections
  • Terminal port emulation
  • Printer driver (alarm/status printer)

Functional Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

ASCII Serial Specifications

The ASCII driver provides a powerful connection between the internal application database in the ProLinx unit and devices supporting serial ASCII communications (bar code scanners, line printers, legacy terminal based computer systems, etc).

The serial port on the gateway is user-configurable to support ASCII communications (Baud rate, Data Bits, Stop Bits, etc). The ASCII port can act as a Master (Send ASCII strings) or as a Slave(Receive ASCII strings), or both.

When configured to send data strings, the transmission of characters strings is easily accomplished by the placement of string data in the module's application database, followed by toggling of a transmit control word. When the ASCII Serial driver detects a change in the transmit control word, the string is sent out the port.

When configured to receive data strings, the module buffers the data until the termination condition is satisfied (as configured by the user) and the receive string is then copied into the module's application data space, with the actual character count value leading the ASCII string data.

The following table provides specifications for the configuration and functionality available on the ASCII serial ports:

ASCII Specifications

Ports

Available in up to four port configurations to receive and/or transmit data.

Receive buffer size

255 bytes

Receive termination

Stream mode, termination characters, message timeout, inter-character delay, or packet size length.

Receive database location

-1 = disable receiver, 0 to 3896

Transmit buffer size

255 bytes

Transmit character with pacing

0 to 65535 millisecond delay between each transmitted character.

Transmit database location

-1 = disable transmitter, 0 to 3896

Communication Configuration

Baud rate

110 to 115,200

Parity

None, Odd, Even

Data bits

7 to 8

Stop bits

1 or 2

RTS On and Off Timing

0 to 65535 milliseconds

Minimum Response Delay

0 to 65535 milliseconds

Hardware or software handshaking

None, RTS/CTS, DTR/DSR, or XON/XOFF

Hardware Specifications

Power Supply 24 VDC nominal
  18-32 VDC allowed
  Positive, Negative, GND Terminals
  2.5 mm screwdriver blade

Current Load

500 mA max@ 32 VDC max
Operating Temperature -20 to 50 Deg C
  -4 to 122 Deg F
Storage Temperature -40 to 85 Deg C
  -40 to 185 Deg F
Relative Humidity 5-95% (w/o condensation)
Dimensions

Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD

LED Indicators

Power and Module Status

  Application Status
  Serial Port Activity LED
  Serial Activity and Error LED Status
  RF Link Status
  RF Data Status
Configuration Serial Port Mini-DIN
  RS-232 only
  No hardware handshaking
Ethernet Port 10Base-T Connector
  Link and Activity LED indicators
  Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
  Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports Mini-DIN
  RS-232/422/485
  RS232 handshaking configurable
  RS422/485 screw termination included
Port Isolation 2500V Opto-Isolators
  500V Power Supply Isolation
Shipped with each unit Mini-DIN to DB-9M cables per serial port
  4 ft RS-232 configuration cable
  2.5mm screwdriver
  CD (docs and Configuration utility)
  RS-422/485 DB9 to Screw Terminal
  Adaptor (1 or 4, depending on ports)
Click here for dimensions diagram

Certifications

The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2


Ordering Information

6201-WA-ASCII

Wireless ASCII Generic Serial Gateway

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested