ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Platform > PLC > MVI71-MNET
Printable Page
 

Search | Clear


Modbus TCP/IP Communications Module

MVI71-MNET

The MVI71 Modbus TCP/IP Communication Module is designed to allow PLC processors to interface easily with other Modbus TCP/IP protocol-compatible devices.

Compatible devices include not only Modicon processors (which support the Modbus TCP/IP protocol) but also a wide assortment of other clients and server devices.

Features and Benefits

The MVI71-MNET module is a single slot solution that provides a powerful connection between Rockwell Automation's PLC processor and Modbus TCP/IP network applications.

The TCP/IP Modbus network applications include those networks hosted by Modicon Quantum processors, networks controlled by operator interface software packages, and the growing number of manufactured devices that support this protocol. The module acts as an input/output module between the Modbus TCP/IP network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus TCP/IP network. A 5000-word register space in the module exchanges data between the processor and the Modbus TCP/IP network.

  • Support for the storage and transfer of up to 5000 registers to/from the PLC processor using the block transfer or side-connect interface
  • User-definable module memory usage
  • 10/100 MB Ethernet compatible interface
  • Configurable parameters for the client including a minimum response delay of 0 to 65535 mSec and floating point support

General Specifications

  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.

Applications

With the growing trend of Ethernet technology in the industrial marketplace, this product has a wide variety of application uses.

  • Food processing
  • Petrochemical
  • Pulp and paper
  • Automobile manufacturing
  • Water and Wastewater
  • Oil and Gas
  • Power and Electric

Functional Specifications

General Protocol specifications

Type

Specifications

Floating Point Data

Floating point data movement supported, including configurable support for Enron and Daniels floating poiont implementations

Supported Function Codes

Function Code Descriptions

FC 1

Read Coil Status (Bits)

FC 2

Read Input Status (Bits)

FC 3

Read Input Registers

FC 4

Read Holding Registers

FC 5

Write Single Coil (Bit)

FC 6

Write Single Holding Register

FC 15

Write Multiple Coils (Bits)

FC 16

Write Multiple Holding Registers

Modbus Server Protocol Specifications

The server driver supports up to ten (10) connections to Modbus TCP/IP Clients using Service Port 502 with the standard MBAP protocol, and up to an additional ten (10) Clients using an other service port for Encapsulated Modbus protocol.

Modbus TCP/IP Client

The Client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.
One Client with up to 100 total commands. (Allows connections to as many as 100 Servers)

Hardware Specifications

Form Factor

Single Slot - 1771 chassis compatible

 

BTR/BTW data transfer

 

Local or remote rack

Backplane Current Load

800 mA @ 5V

Operating Temperature

0 to 60 deg C (32 to 140 deg F)

Storage Temperature

-40 to 85 deg C (-40 to 185 deg F)

Shock

30g operational

 

50g non-operational

Vibration

5g from 10 to 150 Hz

Relative Humidity

5 to 95% (w/o condensation)

LED Indicators

Module status

 

Backplane transfer status

 

Application status

 

Error LED status

 

Link and Activity LED

Configuration Port (CFG)

DB-9M PC compatible

 

RS-232

 

Hardware handshaking

Ethernet Port

RJ45 connector

 

10/100 Mbit Ethernet support (auto-sensing)

 

Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991

 

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Shipped with unit

RJ45 to DB-9M adapter cable for configuration

 

6-foot RS-232 null-modem configuration cable

   

Ordering Information

MVI71-MNET Modbus TCP/IP Communications Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe/Middle East/Africa
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Home : Products : Support : Distributors : Services : News/Events : Contact : ProSoft Tested